Skip to main content

Table 3 Results and analyses of original ERP components

From: Female versus male migraine: an event-related potential study of visual neurocognitive processing

  

Migraineurs

Healthy controls

Statistics

Original ERPs

 

Males

Females

Males

Females

Group F(1,88)

Gender F(1,88)

Group × Gender F(1,88)

P3

Amplitude (μV)

4.321 ± 3.390

2.848 ± 2.613

4.451 ± 3.504

4.911 ± 4.025

12.564**

2.684

9.757**

Latency (ms)

407.130 ± 39.851

404.942 ± 38.794

408.531 ± 37.379

411.034 ± 38.426

1.465

0.003

0.574

N1

Amplitude (μV)

−1.777 ± 1.669

− 2.436 ± 1.991

−2.656 ± 2.267

−2.131 ± 1.951

1.042

0.056

4.434*

Latency (ms)

107.106 ± 30.395

112.700 ± 30.348

112.058 ± 30.020

111.097 ± 33.639

0.212

0.406

0.812

P2

Amplitude (μV)

2.926 ± 2.128

1.915 ± 1.588

2.551 ± 2.366

3.084 ± 3.041

3.043

1.101

11.518**

Latency (ms)

196.391 ± 39.526

193.541 ± 36.700

192.966 ± 35.580

190.720 ± 38.724

0.560

0.373

0.005

N2

Amplitude (μV)

−0.864 ± 2.284

−1.511 ± 1.868

−1.261 ± 2.380

−0.919 ± 2.590

0.104

0.254

2.676

Latency (ms)

281.449 ± 38.000

287.420 ± 32.518

287.444 ± 36.686

283.198 ± 35.468

0.066

0.063

2.203

  1. Data were expressed as mean ± SD
  2. *P < 0.05, **P < 0.01 by repeated-measures ANOVA (Bonferroni correction)